It is a clear cold morning, it has not rained for days, and the underside of your garage or workshop roof is wet from one end to the other. Water is dripping onto the bench, the mower, the car bonn…
Free UK roofing cost calculator Postcode-aware range for your job · 30 seconds Run it →

Condensation Under a Metal Roof: Why It Drips and What Fixes It

It is a clear cold morning, it has not rained for days, and the underside of your garage or workshop roof is wet from one end to the other. Water is dripping onto the bench, the mower, the car bonnet. Somebody has told you the roof is leaking and you are pricing up new sheets.

Almost certainly nothing is leaking. A single skin metal roof makes its own water, and it does it worst on the nights when no rain falls. That matters, because the fix for condensation is not the fix for a leak, and the obvious remedy, more ventilation, is the one thing that will not solve it on a bare sheet.

At a Glance: What Each Fix Costs in 2026

Option Typical UK cost Source and date
Anti-condensation paint, 2.5 litres, covers 20 to 25 square metres £40.36 Specialist Paints Online, accessed 24 Oct 2026
Multifoil quilt below the sheet, 40mm £9.43 per square metre, ex VAT Materials Market, accessed 24 Oct 2026
PIR insulation fitted below £25 to £60 per square metre MyJobQuote, 8 Oct 2026
Insulated composite panels £41.91 to £71.08 per linear metre, ex VAT Roof Sheets Online, last modified 9 Oct 2024
Re-sheeting a single garage in corrugated metal £1,100 to £1,500 MyJobQuote, 2 January 2026
Re-sheeting a double garage £1,800 to £2,500 MyJobQuote, 2 January 2026
Spray foam below the sheet £35 to £70 per square metre MyJobQuote 8 Oct 2026; MyBuilder 21 Aug 2026
Spray foam removal, if you later have to undo it averages £40 per square metre MyJobQuote, 8 October 2026

One caveat: most insulation and sheet suppliers publish no date on their price pages, so those figures carry the date we checked them, and the panel range comes from the only UK supplier we could find publishing a panel price at all.

Why a Bare Metal Sheet Drips, and How to Be Sure It Is Not a Leak

Condensation needs two things: moist air, and a surface colder than the temperature at which that air gives up its water. The second is where metal differs from everything else on a roof. Steel sheet has almost no thermal mass and almost no insulating value, so on a clear night it radiates heat straight out to the sky and keeps going past air temperature. The New Zealand Metal Roofing Manufacturers Association puts a figure on it in its code of practice:

"Radiation to the sky can cause the cladding temperature to drop as much as 5˚C below that of the surrounding air; that causes dew when the surface temperature reaches dew point or frost if the temperature falls below zero."

That is a New Zealand trade body rather than a UK one, but the physics does not change at the border, and the Australian Steel Institute says the same in a 2020 factsheet. The ASI adds a point that matters for a garage or a field shelter: in an open or loosely built structure, outside air circulates freely under the sheeting, so condensation on the underside is expected behaviour rather than a defect.

Add anything that puts moisture into the air below, a car brought in wet, damp firewood, livestock, a kettle in a workshop, and you have a reliable overnight water supply. This is why it is a winter problem and why low pitched roofs suffer more. What you have is what Approved Document C calls surface condensation: the "deposition of liquid water from a vapour, occurring on visible surfaces within the building".

You do not have to guess at which it is, and BRE has published a case where exactly this arithmetic settled it. For about fifteen pounds, buy a humidity meter and an infrared thermometer. Measure the air temperature and relative humidity inside, take the dew point off any dew point table, then point the infrared thermometer at the underside of the sheet. If the sheet is at or below the dew point, the water on it is coming out of your own air and no amount of new roofing will stop it.

Three further signs point the same way: the wetting is spread across whole sheets rather than at one fixing or lap, because a leak has a path and condensation does not; it follows cold clear nights rather than rain; and it is worst on the coldest, most exposed parts of the sheet. If instead a stain runs from one point and worsens during rain, you have a leak, and if it turns out to be an actual leak, here is what to do first.

Why More Ventilation Will Not Fix a Single Skin Sheet

This is the part that trips people up, and where most of the advice online quietly goes wrong.

Roof ventilation guidance in the UK is written around a void. The recommendations are expressed as a free area at the eaves and at high level, sized against the pitch, to flush moist air out of a loft before it reaches the cold deck above. That is the right answer for a house, and how roof ventilation works when there is a loft void to ventilate covers it properly.

A bare profiled sheet on purlins has no void and no ceiling, so there is nothing for those figures to apply to. Worse, the physics works against you: ventilating with outside air lowers the water in the building, but it also drags the inside surface towards outside air temperature, and the sheet is already up to five degrees below outside air on the night it drips. Outside air can sit above the sheet's dew point even after you have opened every door. Ventilation is a precondition for one of the fixes below, not a fix in itself.

The Four Fixes, and What Each One Actually Does

There are only four real options. Two manage the water once it has formed, and two stop the surface getting cold enough to form it at all. That distinction is worth more than any price list.

Anti-Condensation Felt and Anti-Condensation Paint

The standard trade answer when buying new sheets is a felt backing bonded to the underside during profiling. Dripstop, a Freudenberg brand made by FILC, is the best known. Its data sheet specifies a fleece under a millimetre thick holding a guaranteed minimum of 900 grams of water per square metre at nil pitch, 700 at 45 degrees and 500 at 90. Cladco publishes 1,000, 800 and 600 grams as averages, so take the manufacturer's figures as the floor.

It holds water in the fleece until conditions let it evaporate again, which is why it is not a cure. In Cladco's words, "while it can trap condensation, it cannot completely stop it from occurring". The conditions attached are what suppliers rarely spell out:

"Adequate constant ventilation of the roof covering must be ensured in order for Dripstop to dry."

Air in at the gutter, out at the ridge. A pitch above 10 degrees is recommended, and below that drip edges become mandatory to stop capillary action at the laps. It comes on 0.7mm sheets only, and it is permanently bonded, so it cannot be retro-fitted to sheets already on your roof. Cladco no longer publishes a price: the last we can trace is from a brochure printed in August 2020.

For a roof already in place, anti-condensation paint is the only retro-fit here. Coo-Var's version covers 8 to 10 square metres per litre per coat, so a 2.5 litre tin at £40.36 does about 20 to 25 square metres. It leaves a thick, textured film that keeps the surface marginally warmer, and is interior use only. Worth trying on a lightly affected garage. Some retailers claim such coatings eliminate condensation entirely: no test data is cited for that anywhere we looked, so do not buy on the strength of it.

Insulating Below, Composite Panels and the Spray Foam Problem

The other two options attack the cause by keeping the metal warm, or by putting something warmer between you and it.

Insulating below the existing sheet is the usual retro-fit. Rigid PIR board is the common choice, and brand matters: 100mm Celotex runs about £12.78 per square metre excluding VAT against £32.57 for the equivalent Kingspan board. Fitted, MyJobQuote puts PIR at £25 to £60 per square metre including labour as of 8 October 2026. Multifoil quilt is cheaper, at about £9.43 per square metre. Whatever you fit, leave an air gap between insulation and sheet, because the sheet will still go below dew point and that moisture needs to be able to dry.

Replacing the sheets with insulated composite panels is the proper fix and the expensive one. Tata's Trisomet system, also sold through Cladco, publishes U-values of 0.46 for 40mm panels through to 0.20 for 100mm. The catch for a domestic reader is commercial rather than technical: Cladco will only accept Trisomet orders of 100 square metres or more, which rules out most single garages. For re-sheeting costs see what box profile and corrugated sheets actually cost in 2026, and for other coverings garage roof replacement costs for felt, EPDM and fibreglass.

Then there is spray foam, which is cheap, instantly effective and the option to think hardest about. Once foam is bonded to the underside, nobody can inspect the sheet it is stuck to, and the inside face is the face condensation attacks. Tata's Confidex guarantee runs up to 40 years and covers factory cut edges throughout, but the datasheet is explicit that "Confidex has always been restricted to the weathering performance of the external cladding". That 40 year figure says nothing about the face you have just sealed up.

There is a lending problem too, though it is routinely overstated and not really about garages. A BBC survey reported in November 2024 found five of the twenty largest UK lenders would not lend where spray foam is in a roof space, while Lloyds, Nationwide, Barclays, NatWest Group and Santander consider applications case by case. That concerns house roofs rather than outbuildings, but the physical objections apply either way, and removal averages £40 per square metre.

Regional Price Differences, and the Rules Where You Live

There is no regional price data specific to metal roofs or condensation work, and we would rather say so than invent a table. What varies is labour. MyBuilder's roofer price guide of 21 August 2026 gives hourly rates of £40 to £60 in London, £30 to £50 in the South East, £25 to £40 across the Midlands and Scotland and £20 to £35 in the North of England, with day rates of £280 to £360; insulation day rates run lower, from £150.

The more important regional difference is not price at all. In England and Wales, Schedule 2 of the Building Regulations 2010 exempts a detached single storey building of no more than 30 square metres with no sleeping accommodation, provided it is either at least a metre from the boundary or built substantially of non-combustible material, which a typical single garage clears comfortably. In Scotland the equivalent exemption in the 2022 Technical Handbook stops at 8 square metres. A 16 square metre garage needing no approval in Shropshire needs a building warrant in Stirling.

Even where a building is in scope, Approved Document L Volume 2 exempts stand-alone buildings under 50 square metres of useful floor area. For the underlying principle, see the difference between a cold roof and a warm roof.

Want someone to look at it before you buy sheets? Search localroofer.directory to find roofing contractors near you. Say on the phone that the roof drips without rain: that tells a decent roofer straight away this is a condensation job rather than a repair.

Frequently Asked Questions

Will insulating the roof make the condensation worse somewhere else?

It can, if you seal the insulation tight against the sheet. The sheet will still drop below dew point on a clear night, so water will still form, and you want it able to evaporate rather than trapped against board. Leave a ventilated gap, for the same reason anti-condensation felt needs one.

Can I stick anti-condensation felt to the roof I already have?

No. Dripstop and products like it are bonded to the sheet during manufacture and the adhesive is permanent. For a roof already up, the choices are anti-condensation paint, insulating below with an air gap, or replacing the sheets.

My roof is nearly flat. Does that change things?

Yes, twice over. Low pitches collect more condensation because the water has nowhere to run. And anti-condensation felt is recommended only above 10 degrees of pitch; below that, drip edges at gutter and ridge become mandatory to stop capillary action pulling water into the laps. Get the pitch measured before anyone quotes.

How long should a metal roof last, and does condensation shorten it?

A retailer guide puts plain polyester coated sheet at around twenty years, and premium coated products carry guarantees of up to 40 years, but those cover external weathering only. On the inside face no manufacturer publishes a corrosion rate and we found no credible figure for years to failure, so anyone quoting one is guessing. It is a known risk nobody has quantified, which is a reason to deal with it rather than live with it.